PAGE 45
SYMPTOM
Spa Inoperative
Spa Side Inoperative
MESSAGE
BLO
CP
CS
F1 or F2
HC
HP
LB
LP
O3U
P1
P2
Pb
PS
LS
SS
HILI
FLO
ME A N IN G
Power failure outside of spa.
Spa Side could be locked.
Blower Error
HE ET pump may be faulty.
Current Sensor
Blown Fu s e
Heater Error
H i g h Vo l t a g e
Light Error
L o w Vo l t a g e
Ozonator Error
Pump 1 Error
Pump 2 Error
Power Board
Pressure Switch Error
Water Sensor
Heater Sensor
High Limit Sensor Detects
Temperature Rise Above 112 F
Lack of Flow:Heater disabled
AC T I O N
Check power source Breaker and GFCI;
Reset breaker/GFCI. Call Electrician if it will
not start.
If lock icon is visible, unlock by depressing
the “ UP ” button for 5 seconds
Check fuse 3 and then verify that the blower
motor is plugged in.
Check that HE ET pump is plugged in.
Check that current sensor board is plugged
into circuit board.
Replace fuse 1 or fuse 2
Replace heater
High power (voltage) observed. Check power
connections and rerun diagnostic test
Replace underwater light bulb
Low Power (voltage) observed. Check power
connections and rerun diagnostic test
R e p l a c e o z o n a t o r
Check plug for Pump 1
Check plug for Pump 2
Check topside connection and remote panel
connections to power board.
Replace Pressure Switch or Flow Switch
Replace Sensor
Replace Sensor
Allow Spa to Cool, Power Down Spa, Tu r n
Power Back on and Reset Spa Side Control
Remove filter. If “FLO”disappears, clean filter.
D I AG N O S TIC & TROUBL ES H O O T I N G
IF ANY PR O BLEMS PE R S I ST, CALL YOU LOCAL VITA DEALER FOR SERVICE.
IF ANY ERRORS ARE FOUND, THE FOLLOW ING RE PLAC E MENT MESSAG ES MAY BE DISPLAY E D :
Page view 47