PAGE 16
minute, if the water is still below 50
degrees F (10 degrees Celsius), the heater
will turn on and raise the water temperature
10 degrees F.
F. FLOW PROTECTION
If the flow of water through the heater is
insufficient, the spa controller will automat-
ically turn the heater off to prevent over-
heating. The display will show “FLO”, indi-
cating a flow restriction caused by a clogged
filter, shut gate valves or by a malfunction in
the pressure switch. Call for service if you
cannot pinpoint the cause.
G. OVERHEAT PROTECTION
If the water temperature inside the spa
plumbing reaches 112 F, the display will
show “HILI” (High Limit), the heater will be
disabled, and the pumps will be turned on
low speed. If the water temperature contin-
ues to rise and reaches 115 F due to fric-
tion in the pumps and plumbing system,
the entire system including all pumps will
be disabled. In HILI condition, DO NOT
ENTER THE WATER. Remove the cover and
allow the water temperature to cool down
to 104 F. Then, reset the system by holding
down the “PROG” button for 5 seconds
while in time display mode. If the HILI
message returns, call for service.
H. ADD START UP CHEMICALS
Carefully follow the directions and add the
start-up chemicals recommended to you by
your dealer. Contact your dealer to clarify
any questions you may have.
Your spa comes ready for the Vita exclusive
“Sparkle Clear” natural mineral purifica-
tion cartridges. Combined with an ozonator,
“Sparkle Clear” will aid in reducing the need
for Bromine or other chlorine sanitizers.
Sparkle Clear and ozone will make your spa
look cleaner, smell cleaner, feel softer and
eliminate skin or eye irritation. Ask your
dealer about Vita Spa’s “Sparkle Clear”
sanitizing alternative.
C. TURNING ON THE LIGHT
Your spa is equipped with an underwater
light. Press the light button to activate and
de-activate the light. If left on, the light will
automatically turns itself off after 3 hours.
B. MEMORY
All settings that are entered into your spa
controller will be permanently retained in
its solid-state memory. In the event of a
power failure, the time will be captured and
held until power returns. All settings existing
at the time of the power failure will be
restored when power returns.
C. SYSTEM RESET
Anytime there is reason to believe that your
spa electronic system is not operating prop-
erly, perhaps as a result of lightning or other
interference, like your PC at home, your spa
system can be simply reset by holding
down the “DOWN” arrow button for 5 sec-
onds while in the time display mode. The
system will be reset, maintaining all the set-
tings you had in memory.
D. PANEL LOCK
The spa panel can be locked to keep chil-
dren or others from using any of the spa
functions. To deactivate all buttons, make
sure “Time” is displayed. Use “PROG”
button to change to “Time” display if need-
ed. Then hold the “UP” arrow button for 5
seconds. Notice the flashing lock icon. The
panel is locked. To unlock the panel, hold
the “UParrow button for 5 seconds again.
The flashing lock icon will disappear and all
spa functions will be accessible.
E. FREEZE PROTECTION
If temperature in the spa plumbing falls
below 50 degrees Fahrenheit (10 degrees
Celsius) the water pump(s) will turn on
soft-mode and run for at least one minute.
The display will show “ICE”. After one
S P ECIAL FE AT U RES