38
Owners Manual
English
RESTRICTING OPERATION
The control can be restricted to prevent un-
wanted use or temperature adjustments.
From the main screen, activate temperature
ashing. While temperature is ashing, press
“Light” repeatedly until “LOCK” appears on the
screen. Pressing the temperature up button
allows you to toggle through TEMP”, “OFF”
and “ON”.
TEMP” allows you to lock the temp./settings.
ONallows you to lock all settings/functions.
OFF” does not lock the spa.
UNLOCKING
This Unlock sequence may be used from any
screen that may be displayed on a restricted
panel.While pressing and holding the Temper-
ature Up button, slowly press the Light button
twice. “UNLK” will display on the screen and
after a few seconds, will revert to main screen.
ADJUSTING FILTRATION
Main Filtration
Filter cycles are set using a start time and a
duration. Start time is indicated by an A or
“P” in the bottom right corner of the display.
Duration has no A or “P indication. Each set-
ting can be adjusted in 15-minute increments.
The panel calculates the end time and displays
it automatically.
To enter lter cycles, activate temperature
ashing and press the “Light button repeat-
edly until the display reads “FLTR” (with a 1 in
the bottom right corner). Pressing the Light
button will bring you to the display “BEGN”.
The numbers ashing indicate numbers that
can be changed. Scroll through with the up
and down temperature buttons to choose
what time your lter cycle will start and press
the Light button to make your choice. “RUN”
“HRS” will be on the display next. Again, scroll
through the numbers to choose the duration
of your lter cycle.
Filter Cycle 2 - Optional Filtration
Follow the same procedures under “FLTR”
(with a 2 in the bottom right corner) to set up
lter cycle 2.
It is possible to overlap Filter Cycle 1 and Filter
Cycle 2, which will shorten overall ltration by
the overlap amount.
Purge Cycles
In order to maintain sanitary conditions, sec-
ondary Pumps and/or a Blower will purge wa-
ter from their respective plumbing by running
briey at the beginning of each lter cycle.
If Filter Cycle 1 is set for 24 hours, enabling
Filter Cycle 2 will initiate a purge when Filter
Cycle 2 is programmed to begin.
WiFi-CONNECTIVITY
See pages 48-51 to read about your spas Wi-Fi
capabilities. Some spas are equipped with
full Wi-Fi. See your dealer for details if you are
unsure of what your spa should receive.
GFCI TEST FEATURE
A GFCI is an important safety device and is
required equipment on a hot tub installation.
Your spa may be equipped with a GFCI Protec-
tion feature. If so, a GFCI Trip Test must occur
to allow proper spa function.
Within 7 days after startup, the spa will trip the
GFCI to test it. The GFCI must be reset once it
has tripped. After passing the GFCI Trip Test,
the spa will operate normally.