COMMON HARDWARE PROBLEMS
Problem
System not
operating
Heater not
operating
Water not clean
Abnormal
water usage
Overheating
Low water  ow
from jets
Noisy pump
and motor
Usual Cause
- House circuit breaker tripped or
in OFF position
- Water level too low
- Heater mode not selected
- No power to heater
- Clogged or blocked  oor suction
or skimmer
- Filter clogged (dirty)
- Poor water chemistry
- Insu cient ltering time
- Improper maintenance
- High content of solids in water
- Excessive evaporation
and/or splashing
- High ambient temperature
- Operating in FILTER mode-low speed
- Clogged or blocked suction or skimmer
- Dirty lter
- Jets in OFF position
- Slice valves closed
- Clogged oor suction or skimmer
- Low water level
- Damaged or worn motor bearings
Solution
- Reset circuit breaker on house
breaker panel
- Add water to reach 1/8” below
the top of the weir door
- Refer to temperature/heater
functioning. See Control
instructions pg. 20, 26, or 31
- Check house circuit breaker
- Contact dealer
- Clean oor suction/skimmer.
Remove blockage
- Clean or replace
- See Maintenance section
pg. 41
- Run ltration mode longer
- Contact dealer
- Use clari er or drain and re ll spa
- Use spa cover and re ll
as necessary
- Contact dealer
- Select hi-speed jets
- Clean oor suction/skimmer.
Remove blockage
- Clean or replace
- Open jets
- Contact dealer
- Clean oor suction/skimmer
- Add water to normal water level
(15cm below lip)
- Contact dealer