32
VITA SPA DUET
COMMON HARDWARE PROBLEMS
Problem
System not
operating
Heater not
operating
Water not clean
Abnormal
water usage
Overheating
Low water ow
from jets
Noisy pump
and motor
Usual Cause
- House circuit breaker tripped or
in OFF position
- Water level too low
- Heater mode not selected
- No power to heater
- Clogged or blocked oor suction
or skimmer
- Filter clogged (dirty)
- Poor water chemistry
- Insu cient ltering time
- Improper maintenance
- High content of solids in water
- Excessive evaporation
and/or splashing
- High ambient temperature
- Operating in FILTER mode-low speed
- Clogged or blocked suction or skimmer
- Dirty lter
- Jets in OFF position
- Slice valves closed
- Clogged oor suction or skimmer
- Low water level
- Damaged or worn motor bearings
Solution
- Reset circuit breaker on house
breaker panel
- Add water to reach 1/8” below
the top of the weir door
- Refer to temperature/heater
functioning. See Control
instructions pg. 20, 26, or 31
- Check house circuit breaker
- Contact dealer
- Clean oor suction/skimmer.
Remove blockage
- Clean or replace
- See Maintenance section
pg. 41
- Run ltration mode longer
- Contact dealer
- Use clari er or drain and re ll spa
- Use spa cover and re ll
as necessary
- Contact dealer
- Select hi-speed jets
- Clean oor suction/skimmer.
Remove blockage
- Clean or replace
- Open jets
- Contact dealer
- Clean oor suction/skimmer
- Add water to normal water level
(15cm below lip)
- Contact dealer
Comments to this Manuals