Vita Spa DUET Operations Instructions Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
12
VITA SPA DUET
ELECTRICAL INFORMATION
Important Safety Instructions
All electrical connections to this spa package
MUST be accomplished by a quali ed
licensed electrician in accordance with
National Electrical Code (NEC) and with state/
local electrical codes in e ect at the time of
installation.
NOTE: Prior to performing any service to
the spa equipment, turn OFF all primary
electrical power at the main circuit breaker
or disconnect panel.
To make spa electrical connections, remove
the exterior equipment pack service panel,
locate the electrical control box, remove
the control box cover and follow the wiring
diagram on the inside of the control box cover.
Connections should be made using copper
conductors only. Connecting wires, circuit
breakers, or fuses must all be sized to
accommodate the Total Ampere load as
speci ed on the equipment label.
This equipment is designed to operate on
60Hz alternating current only, at 120 volts.
NOTE: All unions must be hand-tight and
all slice valves must be locked in the OPEN
position before  lling or re lling spa!
A clip is provided to help keep the slice
valve open. Run spa and check for union
water leaks before reinstalling exterior
panel.
Ground-Fault Circuit Interrupter
A quali ed licensed electrician shall connect
the spa to a circuit protected by a GFCI. This
is a requirement by the National Electric
Code, article 680-42 and 680-43, and is also in
compliance with Underwriters Laboratories,
Inc.
Installation Options
A hole will need to be drilled in the pedestal
or base to bring the electrical conduit into
the spa cabinet.
Refer to the manufactures’s nameplate
located on the kick plate to determine your
spas ampere requirements.
The Model Duet comes factory set for 120
volt service.
Electrical Requirements:
120 Volt Installation
120 volt, 60 Hz, single phase, 15 amp.,
3-wire service (line 1, neutral, and
ground)
The heater can only be activated with the
pump on low speed. Only the spa light
can be operating at the same time without
disabling the heater.
Caution: Risk of electrical shock.
Read and follow all instructions.
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 39 40

Comments to this Manuals

No comments