Vita Spa Spa Owner's Manual Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
55
VITA SPA
ENGLISHFRANÇAIS
504 SERIES SYSTEM WIRING DIAGRAM
Wiring Diagram For Spa Model Elegant, Monarque, Prestige, Envy, & Grand (240V)
HTR-2
TB1
HTR-1
J101
J100
5.5 kW HEATER
SENSOR A
SENSOR B
TORQUE RANGE
FOR HEATER
CONNECTIONS:
30 TO 35
IN. LBS.
Balboa
K3
K2
K4
RED AC
WHITE AC
BLK AC
F4 0.3A 250V
F7 20A 250V
F1 3A 250V
J32
J33
J66
J65
J61
J62
J34
J36
J23
J37
J74
J35
J11
J15
J16
J25
J63
J64
J73
J46
WHITE
BLACK
RED
L2
L1
N
J50
J47 J29
J20
J17/26
W1
W10
W4
W7
W3
W2
PUMP 1
A V
OZONE
SWITCHBANK A
ON
F5 30A
K6
K1
K9
T1
J43
J12
PERSISTENT
MEMORY
J6
J60
J22
132
J44
VACAUX FRLY
2-S RLY
TST
J13
J7 J8
J1
J2
K5
J18
LIGHT
MX504SZ — PN 55257
01/19/10
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM
THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE
INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.
CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.
USE EARTH GROUND CONNECTIONS
TORQUE RANGE FOR
MAIN TERMINAL BLOCK:
27-30 IN. LBS.
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
#6 AWG MIN. WIRE= 90°
SWITCHBANK A OFF (DOWN)
TOTAL OUTPUT AMP DR
LOCATION DEVICE VO
J23 2 SPD P1 24
J47 12
J17/26 24
J50 AV 12
J29 OZONE 24
J20 LIGHT 12
HTR HEATER 24
CIRC PUMP
CIRC PUMP
# OF HIGH-SPEED PUMPS AND/OR
0 HIGH-SPEED PUMP OR BLOWER
1 HIGH-SPEED PUMP OR BLOWER
2 HIGH-SPEED PUMPS OR 1 HIGH
3 HIGH-SPEED PUMPS OR 2 HIGH
TABLE 1
PUMP 2
1 SPD P2
F5 10A 250V
EXPANDER
X-B
J3
OPTIONAL EXTERNAL RELAY BOARD
K1
J6
J2
W12
LOCATION DEVICE VOLTS AMPS FROM TO
J6 ON BLOWER 240V 8A W12 ON RED AC
EXPANDER EXPANDER
BLOWER
TEST MODE OFF
SEE TABLE 1
PUMP2 DISABLED
AUX FREEZE (MUST BE OFF)
1 SPEED PUMP 1
60HZ
EXT RELAY BOARD DISABLED
DEGREES F
NON CIRC
SEE TABLE 1
K8
CONTROL PANEL
TO J1
INSTALLED WITHIN SIGHT FROM
FEET (1.52 M) FROM THE
, OR HOT TUB.
ECTED BY A CLASS A GFCI.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
ALL UNUSED SWITCHES SHOULD BE OFF
SWITCHBANK A OFF (DOWN) SWITCHBANK A ON (UP)
TEST MODE OFF
SEE TABLE 1
PUMP2 DISABLED
AUX FREEZE (MUST BE OFF)
1 SPEED PUMP 1
60HZ
EXT RELAY BOARD DISABLED
DEGREES F
NON CIRC
SEE TABLE 1
TEST MODE ON
SEE TABLE 1
PUMP2 ENABLED
AUX FREEZE (MUST BE OFF)
2 SPEED PUMP 1
50HZ
EXT RELAY BOARD ENABLED
DEGREES C
CIRC ENABLED
SEE TABLE 1
USE EARTH GROUND CONNECTIONS AS INDICATED INSIDE THE SYSTEM ENCLOSURE
TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RATING OF SPA
LOCATION DEVICE VOLTS AMPS FROM TO
J23 2 SPD P1 240V 12A W1 RED AC
J47 120V W2 WHT AC
J17/26 240V W7 RED AC
J50 AV 120V 2A W4 WHT AC
J29 OZONE 240V 1A W2 RED AC
J20 LIGHT 12V 12W
HTR HEATER 240V 4.0kW HTR TERM HTR 1/2
CIRC PUMP 4A
# OF HIGH-SPEED PUMPS AND/OR BLOWER WITH HEATER
0 HIGH-SPEED PUMP OR BLOWER
1 HIGH-SPEED PUMP OR BLOWER
2 HIGH-SPEED PUMPS OR 1 HIGH-SPEED PUMP AND BLOWER
3 HIGH-SPEED PUMPS OR 2 HIGH-SPEED PUMPS AND BLOWER
TABLE 1
A2
OFF
ON
OFF
ON
A10
OFF
OFF
ON
ON
1 SPD P2 12A
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59